Categories
- Agitators & Mixers (21)
- Blower (27)
- Boiler (26)
- Centrifuge (29)
- Columns (21)
- Compressor (23)
- Conveyor (46)
- Electrical (161)
- Elevator Leg (9)
- Filter (69)
- Heat Exchanger (99)
- HVAC (5)
- Infrastructure (9)
- Instrument (63)
- Lab (6)
- Material Handling (43)
- Misc (6)
- Office (1)
- Packaging (22)
- Piping (100)
- Plants (13)
- Presses & Extruders (5)
- Process (125)
- Pump (153)
- Refrigeration (5)
- Scrap Value (1)
- Silo (1)
- Spare Parts (1)
- Systems & Packages (28)
- Tank, Carbon Steel (20)
- Tank, Poly (1)
- Tank, Stainless (75)
Locations
- (2)
- Alabama (4)
- Amarillo, TX (1)
- Athens, AL (1)
- Beaver Dam, WI (1)
- Bethany, MO (2)
- California (1)
- Canada (3)
- Canton, IL (333)
- Chattanooga, TN (4)
- China (1)
- Cleveland, OH (1)
- Dayton, OH (1)
- Decatur, IN (1)
- Eaton Rapids, MI (1)
- Elkhart, IN (1)
- England (5)
- Escondido, CA (3)
- Europe (2)
- Florence, SC (1)
- Florida (4)
- Ft. Worth, TX (40)
- Grant City, MO (49)
- Houston, TX (4)
- Hutchinson, KS (1)
- Idaho (1)
- Illinois (24)
- Indiana (2)
- Iowa (6)
- Jacksonville, IL (1)
- Jacksonville, IL (143)
- Kansas (33)
- Kansas City (1)
- Kingston, Jamaica (5)
- Loves Park, IL (2)
- Marissa, IL (7)
- McAllen, TX (1)
- Mexico (3)
- Midwest (1)
- Minnesota (2)
- Missouri (5)
- MN (5)
- Moberly, MO (2)
- Montana (2)
- Morris, MN (20)
- Nebraska (2)
- New Jersey (6)
- New York (1)
- North Carolina (1)
- Ohio (1)
- Pennington Gap, VA (2)
- Saskatchewan, Canada (2)
- Soperton, GA (98)
- South Carolina (1)
- Southeast (5)
- Southeast US (2)
- Southeast USA (1)
- Spain (1)
- Springfield, MO (1)
- Staten Island, NY (1)
- Texas (18)
- Turkey (1)
- USA (1)
- Vernon, CA (3)
- Vicksburg, MS (320)
- Virginia (2)
- Williamstown, NJ (1)
- Wilmington, NC (1)
- Windsor, NJ (1)
- Winnebago, MN (1)
- Wisconsin (6)
- Worth, MO (1)
Triton Bearing Blower. Part of FluidQuip BOS system (See asset FQ-BOS). Not sold separately at this time.
Clarifier Bearing Blower. Part of FluidQuip BOS system (See asset FQ-BOS). Not sold separately at this time.
Gardner Denver Series 45 Duro Flow positive displacement lobe blower vacuum pump. Model GGDECDA, Cat # 4518. Used - in service. Rated at rpm from 1750 to 4000, cfm to 1875, vacuum to 16Hg. See link for data sheets.
Air Blower capacity ACFM Driven by 5HP motor, Material CS. Used as Dust Filter Reverse Air Blower under FA-1301. Part of Baghouse - priced with baghouse
Kice blower fan, Model FA33 ARR 9F, with inlet duct/transition. Fan is carbon steel with 36 inch inlet/outlet and 33 inch wheel. Airfoil fan wheel. Includes outlet duct/stack stainless steel duct 29" dia x 40 ft tall. Includes baseplate 60HP motor - no motor. Serial numbers 250431-4 & 250431-11. The fan has not been reconditiond but the motor has. Depending on motor rpm, HP, and sp - cfm can be between 11,267 cfm and 25,039 cfm. See chart in links. This blower was sized for a baghouse silo (asset cp101) - both can be purchased together. Price here is for Blower/motor/stack only. Removed and ready to load
Combustion fan for ring dryer by Twin City Fan & Blower. Type HIB, Arr 1. Width SW, size 360, rotation CCW. Rated at 26,211 cfm at 21.3 sp. Sn 07-234050-2-1. Driven by 150 HP motor 1800 rpm 460/3/60. Size approx 114" x 64" x 102". Used as combustrion fan FANC-11 for ring dryer. Part of ring dryer DR-5210, not sold separately at this time. For a list of components and their photos & description enter dr5201 in search box on web site
Twin City blower with 150HP motor. Designed for 22,975 cfm at 32.3" WC static pressure. Model HIB-SW, size 400, sn 07-234050-1-1. Driven by 150HP motor 1800 rpm 460/3/60. Overall size 60" diameter x 61" wide x 75" high. Used as ring dryer components fluid bed cooler (dryer) exhaust FANC-31. Part of ring dryer DR-5210, not sold separately at this time. For a list of components and their photos & description enter dr5201 in search box on web site
Belt driven blower, Kice model FC15 9FB sn 266261-1. Driven by 15/460/1800/254T (HP/voltage/rpm/frame). Flow approx 4000 cfm at 5" wc SP. Physical size approx 56" long x 51" wide x 40" tall. Part of Process Scrubber Package PK-3201, not sold separately at this time. For a list of all components, enter pk3201 in search box on web site
IAP Fan Model 23-84. Fan capacity 22,562 cfm at 33" sp, 2062 rpm. Fan is P Design 50 Arr 1Z. Driven by a v-belt 200 HP motor 1800 rpm. Electric actuated damper. Used as Fluid Bed Dust Collector Fan on Dryer system. Part of fluid bed cooler package - enter PK5430 for a list of all components.
Blower fan by Quality Industrial ser num 16184-2. Driven by a 25 HP motor, 1770 rpm 460/3/60. Used as hammermill blower #1
Blower fan by Quality Industrial ser num 16184-2. Driven by a 25 HP motor, 1770 rpm 460/3/60 Used as hammermill blower #2
Fan sized for 2,260 acfm at 41.4" wc. Driven by 25 HP motor. Used as south RTO combustion fan. Part of RTO system Z-5201.. For a complete list of components, enter z5201 in search box.
Fan sized for 2,260 acfm at 41.4" wc. Driven by 25 HP motor. Used as north RTO combustion fan. Part of RTO system Z-5201.. For a complete list of components, enter z5201 in search box.
Northern Blower capacity 1400 ACFM @ 3.5 "WC Driven by 2 HP motor 1800 rpm Material 304 SS Size 7, Model 22, 100% SISW, ARR 9, Rot CW, TAU With outlet damper. Used as Centrate Blower in decanting.
New York Blower, size A13913-100. Wheel 2410 steel. 2,000 cfm at sp 50" wc. BHP 23.5, rpm q550, VCW rotation. Driven by 30 HP motor. The entire system is available, however, we will sell equipment individually. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box
[PRELIM - Seller may want to keep. Make OFFER]. Northern Blower Process Vent Scrubber Fan capacity 1000 CFM @ 3.5 "WC HP 7.5 RPM 1800 Material 304 SS Size 7 Model 22 100% SISW ARR 9 Rot CW TH discharge with outlet damper. V-belt drive by 7.5 HP motor 1760 rpm. For more detailed data - see links. This unit is part of the scrubber Package. For a list of that package and all components, enter "PK3501" into the keyword search box.
Blower fan used as an induced draft fan. Designed for122,740 acfm at 26.5 " wc. Fan driven by a 700HP motor 4160v 1785 rpm. TEFC frame 5811. Fan mfg Garden City. , arrgt 8, SWSI, CW rotation, top horizontal discharge. Size 60, type RT, design 600. sn C298700. Used as induced draft fan on RTO. Part of RTO system Z-5201, For a complete list of components, enter z5201 in search box.
NY Blower Direct drive blower driven by 10HP motor 10/460/3600/215T. Model 2303 steel, pressure blower. Designed for 200 cfm at 52.2 sp. Last inspected 9/2018. Used for CO2 flash tank blower
Robinson Fan type 97" x 11-1/4" BI1120, Arr 3. Designed for 189,339 scfm at 30" sp. Material ss316 sn DA-98BI1120-118. Driven by 1200 HP motor Mfg TECO Type AEJH-TK, frame 1185 rpm. Weight 29,571 pounds w/o motor. Motor weight 15,848 pounds. Physical size (w/o motor)" 149" wide x 119" deep x 186" tall. Used as Main ring dryer fan FANC/12. Part of ring dryer DR-5210, not sold separately at this time. For a list of components and their photos & description enter dr5201 in search box on web site
Tuthill Ash Blower 60 HP blower. Model 4612-46L2. Complete skid Used to blow ash from baghouse hopper discharge - CoGen. The entire system is available, however, we will sell equipment individually. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box.
Centrifugal blower mfg by New York Blower. This is a 30 CI fan belt-driven by 7.5HP Baldor motor, 2000 cfm at 800F, 7.5 s.p. This fan is in excellent condition, having run only 42 days. Built 2008. Removed - ready to load. NOTE: <Main photos show screw feeder still installed. It has now been removed and is in the laydown yard. See other photos>
Robinson FD Fan; Type RB1216, size 65x11 1/2. Designed for 77,800 cfm at 50" sp. Direct Driven by 1000 HP motor, 1800 RPM 4160v, Used as FD fan at CoGen boiler. The entire system is available, however, we will sell equipment individually. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box.
ID Fan 23,657 cfm at 23 " sp. Mfg by Northern Blower Design 4370, Size 3650. Arrt 1S1, CCW rot. Fan material cs. Driven by Baldor 125 HP motor 460/3/60 , RPM 1800, TEFC. Belt driven. Physical size skid 93" x 94" x 85" tall. See link for drawings and data. Used as Dryer Stage 2 ID Fan. Part of Dryer #2 ancillary package - enter PK5420 for a list of all components.
ID Fan 29,613 cfm at 23 " sp. Mfg by Northern Blower Design 4370, Size 4025-4425. Arrt 1S1, CCW rot. Fan material cs. Driven by Baldor 150 HP motor, RPM 1800, TEFC. Belt driven. Physical size skid 99" x 108" x 93" tall. See link for drawings and data. Used as Dryer No 1 ID Fan. Part of Dryer #1 ancillary package - enter PK5410 for a list of all components.
Robinson ID Fan designed for 96,555 cfm at 19" sp. 600 HP Motor 1200 rpm 4160v. Used as ID Fan at ash baghouse & bin; CoGen. The entire system is available, however, we will sell equipment individually. See Simplified Flow Chart in Links for a pictorial of each piece in this system. For a list of all components, enter PK9140 in the search box.